Australian Codes and Standards

To fully comply with current codes and standards, all *public access stairs must

  • be fitted with stair edgings that have a fully non slip horizontal surface;
  • have stair edgings measuring a minimum of 50mm wide and
  • have stair edgings with a luminance contrast of at least 30 percent against the surface they are fixed to

Guardian Non Slip Tapes meet or exceed these requirements and when fitted will ensure the building owner fully meets the duty of care obligations to the public as outlined in these Codes and Standards

Statutory CSIRO Approvals

Guardian have complied with the test criteria requirements of the CSIRO and Australian standards in conjunction with:

AS / NZS 4586: 2004 ResultClassDate
Oil - Wet Ramp Test 36.4R13 PDF file August 2008
Wet Pendulum Test 80V PDF file August 2008
CSIRO Accelerated Wear Test (CAWT)
RevolutionsMean BPNClassDate
080V PDF file September 2008
10078 (2.5% loss)V
50076 (5.0% loss)V

National Construction Code (NCC)

The National Construction Code (NCC), formally known as the Building Code of Australia (BCA) is calling for non slip stair edging to be used in accordance with:

  • National Construction Code (NCC)
    Volume 1 - Construction of Exits
    • Goings and Risers. Section D2.13 (a) (v)
    • Landings. Section D2.14 (a) (ii)
  • National Construction Code (NCC)
    Volume 2 - Stair Construction
    • Section 3.9.1.3 (g)

Australian Standards

The Building Code of Australia calls for non slip stair edging to be used in accordance with:

  • Australian Standards AS 1428.4.1 - 2009
    Design for access and mobility - new building work.
    Stairways - Part 9.1c
  • Australian Standards AS 1428.4 - 2002
    Design for access and mobility - new building work.
    Stairways - Part 9.1c
  • Australian Standards AS 1428.1 - 2001
    Design for access and mobility - new building work.
    Stairways - Part 9.1c
  • Australian Standards AS 1428.2 - 1992
    Design for access and mobility - new building work.
    Stairways - Part 13.3

Compliance with New Public Access Standards

Guardian non slip stair Tapes will ensure owners provide an accessible accessway* to and within their buildings in compliance with the requirements of the Building Code of Australia and Australian Standards

* a continuous path of travel, having features to permit use by people with disabilities as defined in AS 1428.4.1.2009